New D-PEXE-IN-A-00 Test Price - 100% Newest Questions Pool

Rated: , 0 Comments
Total visits: 50
Posted on: 12/18/24

The D-PEXE-IN-A-00 prep guide adopt diversified such as text, images, graphics memory method, have to distinguish the markup to learn information, through comparing different color font, as well as the entire logical framework architecture, let users on the premise of grasping the overall layout, better clues to the formation of targeted long-term memory, and through the cycle of practice, let the knowledge more deeply printed in my mind. The D-PEXE-IN-A-00 Exam Questions are so scientific and reasonable that you can easily remember everything.

EMC D-PEXE-IN-A-00 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Unpacking the server: This section of the exam covers safely removing the server from its packaging, inspecting for damage, and identifying all included components.
Topic 2
  • Putting the server into the rack: This section of the exam includes securely mounting the server in a compatible rack, ensuring proper airflow and cable management.
Topic 3
  • Pre-installation tasks: This section involves preparing the environment and server for installation, including reviewing documentation, gathering tools, and verifying the proper workspace.
Topic 4
  • Connecting power and network cables: This domain covers connecting the server to a power source with the appropriate cable and voltage, and connecting it to the network using compatible cables.

>> New D-PEXE-IN-A-00 Test Price <<

Cert D-PEXE-IN-A-00 Guide & Updated D-PEXE-IN-A-00 Demo

With our high efficient of D-PEXE-IN-A-00 learning materials you may only need to spend half of your time that you will need if you didn't use our products successfully passing a professional qualification exam. In this way, you will have more time to travel, go to parties and even prepare for another exam. The benefits of D-PEXE-IN-A-00 training torrent for you are far from being measured by money. We have a first-rate team of experts, advanced learning concepts and a complete learning model. The time saved and the guaranteed success for you with our D-PEXE-IN-A-00 learning materials is the greatest return to us.

EMC Dell PowerEdge XE9680 and XE8640 Install Sample Questions (Q10-Q15):

NEW QUESTION # 10
A deployment engineer installed and powered on a XE8640 server. The Linux operating system is installed.
They need to update the drivers on the server.
What is a consideration before updating the driver?

  • A. A single graphics driver supports all modern GPUs.
  • B. The driver package only supports Windows operating systems.
  • C. Each GPU model has a distinct driver package.
  • D. You can upload the driver package using the iDRAC UI.

Answer: C

Explanation:
* Understanding GPU Drivers:
* Graphics Processing Units (GPUs) require specific drivers to ensure optimal performance and compatibility with the operating system. Each GPU model typically has a unique driver package designed to leverage its capabilities and architecture.
* Driver Packages for Different GPU Models:
* For the Dell PowerEdge XE8640, which may be equipped with multiple GPU models, it is crucial to identify the exact GPU models installed in the server. Each GPU model, whether it's from NVIDIA, AMD, or another manufacturer, will have a distinct driver package.
* Importance of Model-Specific Drivers:
* Using the correct driver for each GPU model ensures that the GPU operates efficiently, provides the intended performance, and remains stable under various workloads. Incorrect drivers can lead to suboptimal performance, compatibility issues, or system instability.
* Steps to Update Drivers on Linux:
* Identify the GPU models installed in the server. This can be done using commands likelspci | grep
-i vgaor similar tools that list the hardware components.
* Visit the GPU manufacturer's website (e.g., NVIDIA, AMD) to download the appropriate drivers for each GPU model.
* Follow the manufacturer's installation instructions, which typically involve downloading the driver package, extracting it, and running an installation script or using package management tools.
* Using iDRAC for Driver Updates:
* While the iDRAC (Integrated Dell Remote Access Controller) UI can be used for various management tasks, uploading driver packages directly via iDRAC is not typically supported.
Drivers are usually installed within the operating system environment.
* Compatibility with Linux:
* Ensure that the driver package is compatible with the Linux distribution and kernel version installed on the XE8640. GPU manufacturers often provide detailed compatibility information and installation guides specific to various Linux distributions.
* Reference to Official Documentation:
* Dell's support site and the GPU manufacturer's documentation provide comprehensive guides on downloading and installing the correct drivers for various operating systems, including Linux.
References:
* Dell EMC PowerEdge XE8640 Installation and Service Manual: This manual provides detailed guidelines on hardware configurations and driver installations.
* NVIDIA/AMD Official Documentation: These resources offer specific instructions on downloading and installing GPU drivers for different operating systems and GPU models.


NEW QUESTION # 11
A deployment engineer is installing eight PowerEdge XE9680 servers. Two servers will be installed in each of four racks. The data center managers must plan for the power needed to supply power to the four racks.
What power consumption information can the deployment engineer give the data center manager?

  • A. Each rack must power 12, 2800-Watt, 15.6 Amp PSUs.
  • B. Each rack must have at least 6 PDUs for power high availability.
  • C. Each PDU must use a C20-type connection.
  • D. Each server has four 2800-Watt, 15.6 Amp PSUs.

Answer: D

Explanation:
The PowerEdge XE9680 server is equipped with power supply units (PSUs) that are essential for its operation.
Here's the power consumption information that the deployment engineer can provide:
* PSU Specifications: Each PowerEdge XE9680 server comes with four 2800-Watt, 15.6 Amp PSUs1.
This specification is crucial for the data center manager to understand the power requirements for each server.
* Total Power Requirement: With two servers per rack, each rack will have a total of eight 2800-Watt PSUs. This information helps in calculating the total power draw for each rack.
* Power Distribution Units (PDUs): While the number of PDUs required for high availability can vary, it's important to note that the server's PSUs feature a C22 input socket1. The data center manager should ensure that the PDUs in the rack are compatible with this type of connection.
* Power Planning: The data center manager must plan for the power needed to supply power to the four racks, considering the power draw of the servers and any additional equipment that will be installed.
By providing this detailed power consumption information, the deployment engineer assists the data center manager in planning for the appropriate power infrastructure to support the PowerEdge XE9680 servers.


NEW QUESTION # 12
A deployment engineer is installing an XE9680 server. The network connectivity has 24 optical cables that route to switches in the data center. The administrator questions the use of a cablemanagement arm (CMA).
What are two items to consider when installing a CMA?

  • A. Do not route optical cables through the CMA.
  • B. The XE9680 does not support a CMA.
  • C. A CMA can only be installed with a strain relief bar.
  • D. The CMA can be installed to open on either the left or right side of the server.

Answer: A,D

Explanation:
When installing a Cable Management Arm (CMA) on the Dell PowerEdge XE9680 server, there are specific considerations to ensure proper installation and operation:
* CMA Orientation:
* Installation Flexibility:The CMA for the XE9680 can be installed to open on either the left or right side of the server. This flexibility allows for better management of space within the rack and ensures that the CMA can accommodate the specific layout of your data center(Dell)(Dell).
* Cable Routing:
* Avoid Routing Optical Cables Through the CMA:Optical cables are typically more sensitive and less flexible compared to other types of cables. Routing them through the CMA can lead to bending, twisting, or other stresses that may damage the cables and affect network performance.
Therefore, it is advised not to route optical cables through the CMA(Dell)(Dell).
* Installation Process:
* Align and Install the CMA:Attach the CMA to the designated mounting points on the server rails.
Ensure that it is securely fastened and aligned properly to avoid any issues when extending or retracting the server from the rack.
* Organize Cables:Use the provided cable management features to route and secure other cables, ensuring they are not pinched or overly stressed. Avoid including optical cables in the CMA to prevent potential damage.
* Post-Installation Checks:
* Verify Movement:Ensure that the server can be smoothly extended and retracted with the CMA in place without any cables getting caught or strained.
* Secure Connections:Double-check all cable connections to ensure they are secure and functioning correctly.
These steps are crucial for maintaining the integrity and performance of the server and the connected network infrastructure. Proper cable management not only ensures safety but also enhances the reliability and maintainability of the data center setup.
References:
* Dell PowerEdge XE9680 Installation and Service Manual(Dell).
* Dell XE9680 Rack Rail with Cable Management Arm Information(Dell)(Dell).


NEW QUESTION # 13
A deployment engineer is installing a PowerEdge XE8640 server. The server is on a lift, and they have aligned the server inner rails with the rail assemble that are secured in the rack. The engineer can only push the server into the rack a short distance before it stops. Pushing forcefully causes the rack to slide back.
What action should the deployment engineer take?

  • A. Lower the lift and move away from the server.
  • B. Pull the server out of the rack and realign the lift with the rack.
  • C. Have a person hold the rack while using force to slide in the server.
  • D. Press the mechanism on the rail to release the rail lock.

Answer: D

Explanation:
* Understanding Rail Locks:
* The PowerEdge XE8640 server rails are equipped with a locking mechanism to secure the server during transport and installation. This prevents the server from moving unintentionally and ensures stability.
* Identifying the Issue:
* When the server stops after being pushed only a short distance into the rack, it is likely due to the rail lock engaging. This lock must be released to allow the server to slide fully into place.
* Releasing the Rail Lock:
* Locate the rail lock mechanism on the rails. This is typically a lever or button that, when pressed, releases the lock, allowing the server to slide further into the rack.
* Detailed Steps:
* Align the Server: Ensure that the server is properly aligned with the rails before proceeding.
Misalignment can cause the server to get stuck or make it difficult to release the lock.
* Press the Release Mechanism: With the server partially inserted, locate and press the release mechanism on both sides of the rails. This should disengage the locks.
* Slide the Server: Once the locks are released, carefully push the server into the rack until it is fully seated. Ensure that the server is evenly aligned to avoid binding or getting stuck.
* Avoiding Forceful Methods:
* Avoid using excessive force to push the server into the rack as it can cause damage to the server, rails, or rack. Additionally, pushing forcefully without releasing the rail lock can lead to misalignment and potential hardware issues.
* Safety and Assistance:
* Ensure the lift is stable and properly aligned with the rack to prevent movement. If needed, have an assistant stabilize the lift while performing the installation steps.
* Reference to Official Documentation:
* Refer to the Dell EMC PowerEdge XE8640 Installation and Service Manual for specific instructions and diagrams illustrating the rail lock mechanism and proper installation procedures.
References:
* Dell EMC PowerEdge XE8640 Installation and Service Manual: This manual provides detailed guidelines on the proper use of rail kits and the mechanism for releasing rail locks during server installation.
* Dell EMC Technical Specifications Guide: Offers comprehensive details on the hardware specifications and installation processes for Dell PowerEdge servers, including rail systems and locking mechanisms.


NEW QUESTION # 14
A deployment engineer is preparing to install three PowerEdge XE9680 servers in a rack supplied by the customer.
What must they before going on-site to install the servers?

  • A. The customer completed the required training on the server.
  • B. The rack has at least six PDUs and two power sources.
  • C. The rack will have a top-of-rack switch.
  • D. The rack can accommodate the length of the servers.

Answer: D

Explanation:
* Server Dimensions and Rack Compatibility:
* The Dell PowerEdge XE9680 is a large server with specific dimensional requirements. Ensuring that the customer's rack can accommodate the physical length and depth of the server is crucial for a successful installation.
* Rack Depth and Space Requirements:
* Measure the depth of the customer's rack to ensure it is sufficient to house the XE9680 servers.
The server's dimensions, including its length, should be verified against the available space in the rack.
* Server Length Specification:
* The PowerEdge XE9680 has a significant depth, typically around 800mm (31.5 inches). The rack must be deep enough to support the full length of the server, including any cable management and airflow requirements.
* Checking Rack Specifications:
* Verify that the rack adheres to standard dimensions suitable for hosting enterprise-grade servers.
Ensure that the rack has appropriate mounting options, such as square or threaded holes compatible with the server's rail kit.
* Pre-installation Verification:
* Before arriving on-site, confirm with the customer that their rack meets the necessary specifications. This includes checking for sufficient clearance at the rear for cable connections and at the front for proper airflow.
* Importance of Proper Fit:
* A rack that cannot accommodate the length of the servers will result in installation failure, potential damage to the hardware, and inefficient cooling. It may also pose safety risks during and after installation.
* References and Documentation:
* The Dell EMC PowerEdge XE9680 Installation and Service Manual provides detailed information on the server's dimensions and the necessary rack specifications. This manual should be consulted to ensure all pre-installation requirements are met.
References:
* Dell EMC PowerEdge XE9680 Installation and Service Manual: This manual provides comprehensive guidelines on the server's physical dimensions and the necessary rack specifications for proper installation.
* Dell EMC Technical Specifications Guide: Offers detailed specifications and requirements for rack compatibility and server installation procedures.


NEW QUESTION # 15
......

The Dell PowerEdge XE9680 and XE8640 Install has become very significant to validate expertise and level up career. Success in the Dell PowerEdge XE9680 and XE8640 Install exam helps you meet the ever-changing dynamics of the tech industry. latest Dell PowerEdge XE9680 and XE8640 Install D-PEXE-IN-A-00 Exam Cram Pdf, collection pdf and exam dumps have been provided in TroytecDumps. With 365 days updates.

Cert D-PEXE-IN-A-00 Guide: https://www.troytecdumps.com/D-PEXE-IN-A-00-troytec-exam-dumps.html

Tags: New D-PEXE-IN-A-00 Test Price, Cert D-PEXE-IN-A-00 Guide, Updated D-PEXE-IN-A-00 Demo, D-PEXE-IN-A-00 Online Test, D-PEXE-IN-A-00 Frenquent Update


Comments
There are still no comments posted ...
Rate and post your comment


Login


Username:
Password:

Forgotten password?